Spring Rate Calculator

Calculate spring rate from shear modulus, wire diameter, mean coil diameter, and active coil count.

Result
—

How to calculate

Use Gd⁴ divided by eight times mean diameter cubed and number of active coils. From the rate, divide applied load by stiffness to get linear deflection.

Worked example

Use Wire shear modulus (GPa) 80 · Wire diameter (mm) 2 · Mean coil diameter (mm) 20 · Active coil count 5. The result is ≈ 4 N/mm.

Input and result notes

Use active coils only. The design estimate assumes linear response and does not account for coil binding or fatigue.

MW Components coil spring design guide

Related calculators