How to calculate
To convert ACFM to SCFM, multiply by the ratio of actual pressure to reference pressure and by the ratio of reference temperature to actual temperature on an absolute scale. Divide by both ratios for the reverse conversion.
Worked example
Use Convert ACFM to SCFM · Volumetric flow (ft³/min) 100 · Actual absolute pressure 29.4 · Reference absolute pressure 14.7 · Temperature unit Fahrenheit · Actual temperature 68 · Reference temperature 68. The result is ≈ 200 SCFM.
Input and result notes
Use matching absolute pressure units such as psia for both fields. Add the local atmospheric pressure to gauge readings first. Use the reference conditions stated with your flow rate. The calculator assumes ideal-gas behavior and unchanged composition.
NIST pressure and gas flow unit conversions