Reverberation Time Calculator

Estimate room reverberation time RT60 with the Sabine equation, using floor, ceiling, wall, door, and window absorption coefficients.

Result
—

How to calculate

Multiply each boundary area by its absorption coefficient. Deduct doors and windows from wall area and use their own coefficients. Add any equivalent absorption from furnishings or people. Divide 0.161 times the room volume in cubic meters by total equivalent absorption area in metric sabins.

Worked example

Use Room length (m) 6 · Room width (m) 4 · Room height (m) 3 · Floor absorption coefficient 0.1 · Ceiling absorption coefficient 0.3 · Wall absorption coefficient 0.08 · Combined door area (m²) 2 · Door absorption coefficient 0.1 · Combined window area (m²) 3 · Window absorption coefficient 0.05 · Additional equivalent absorption area (m² sabins) 0. The result is ≈ 0.8078048780488 s.

Input and result notes

Use absorption data for one common frequency band, such as 500 Hz. An empty opening category can use zero area. Sabine assumes a diffuse field and is generally used for rooms with modest average absorption.