Orifice Flow Calculator

Find incompressible discharge through an orifice from area, differential head and discharge coefficient.

Result
—

How to calculate

Multiply the orifice area and discharge coefficient by the square root of twice gravity times differential head.

Worked example

Use Cross-sectional area (m²) 0.005 · Differential head (m) 0.5 · Discharge coefficient 0.62. The result is ≈ 0.009707827074068 m³/s.

Input and result notes

Use a discharge coefficient appropriate to the geometry and operating conditions.

OpenStax fluid dynamics

Related calculators