NPSH Calculator – Net Positive Suction Head

Calculate available net positive suction head and compare it with the pump’s entered required NPSH.

Result
—

How to calculate

Divide absolute reservoir pressure minus liquid vapor pressure by density times gravity. Add static suction head and subtract suction friction losses.

Worked example

Use Fluid density (kg/m³) 1000 · Absolute pressure above suction reservoir (kPa) 101.325 · Absolute vapor pressure (kPa) 3.2585 · Reservoir surface above pump datum (m) 0 · Suction system head loss (m) 1 · Manufacturer required NPSH (m) 3. The result is ≈ 9 m.

Input and result notes

Use absolute pressure and the vapor pressure at the pumped liquid’s temperature. Enter negative static head for suction lift.