Impedance Matching Calculator

Design an L-network to match complex source and load impedances at one frequency. Compare series and shunt capacitor or inductor values.

Result
—

How to calculate

Solve for the series reactance and shunt susceptance that make the input impedance equal the complex conjugate of the source. Convert each reactive value to a capacitor or inductor at the selected frequency.

Worked example

Use Operating frequency 100 · Frequency unit MHz · L-network topology Show both placements of the shunt arm · Source resistance (Ω) 50 · Load resistance (Ω) 100. The result is ≈ 79.577471546 nH series, ≈ 15.915494309 pF shunt.

Input and result notes

Use positive reactance for inductive behavior and negative for capacitive. Values assume ideal lumped components and one frequency. Component losses, tolerances, parasitics, and DC paths can limit practical use.