Flyback Converter Calculator

Estimate isolated flyback duty cycle, magnetizing current ripple, and switch and diode stress in continuous conduction.

Result
—

How to calculate

Multiply input voltage by the secondary-to-primary turns ratio and by duty cycle divided by one minus duty cycle. Check conduction from average current and half the modeled ripple.

Worked example

Use Find Duty cycle from output voltage · DC input voltage (V) 48 · Output voltage magnitude (V) 12 · Output load current (A) 2 · Switching frequency (kHz) 100 · Primary magnetizing inductance (µH) 100 · Effective output capacitance (µF) 100 · Efficiency for input current estimate (%) 90 · Secondary turns per primary turn 0.25. The result is ≈ 50 %.

Input and result notes

The model uses ideal continuous-conduction equations and reports when the selected load crosses the conduction boundary. Verify component and controller limits separately, including parasitic voltage spikes and transient behavior.

Texas Instruments continuous-conduction flyback design

Related calculators